Powercom Macan MRT 1000VA/1000W On Line UPS Rack/Tower (MRT-1000)
Actual product may differ
- 5099577
- MRT-1000
- Powercom
- Uninterrupted power supply (UPS)
Product was discontinued 13 Aug 22
Don’t worry, we may have more Uninterrupted power supply (UPS) from Powercom in stock.
Overview
The Macan Rack/Tower (MRT) series is a new generation of UPSs combined with advanced technology and an output power factor of 0.99+ (extremely efficient) to perfectly protect your system.
Features
- Battery hot swappable design
- Pure Sine Wave output with less than 2.5% THD
- True double conversion
- Diagram LCD display
- UPSMON Pro and APP Support
- 50/60Hz frequency converter mode
Specs
Capacity | Capacity VA/W | 1000/1000 |
---|---|---|
Input | Nominal Voltage | 208V/220V/230V/240V |
Voltage Range | 120~140V under 25% load 140~160V under 50% load 160~180V under 75% load 180~276V under 100% load |
|
Frequency | 50Hz to 60Hz auto sensing | |
Output | Voltage (on battery) | 208V (derating 90%, 220V/230V/240V ±2% (selectable output voltage) |
Frequency (on battery) | 50Hz/60Hz ±0.25Hz | |
Wave form | Pure sine wave | |
Transfer time | 0ms | |
Overload recovery | Auto transfer to UPS | |
Harmonic Distortion | ≤ 2.5% THD at linear load | |
Normal efficiency mode (AC to AC) | 90% | |
High efficiency mode (AC to AC) | > 95% | |
Cress factor | 3:1 | |
Connections | Standard IEC C13 | |
Protection | Surge Protection | 230V (IEEE C61000-4-5 level 3) |
Overload protection (on main) | 105~120% for 30 seconds and 121~150% for 10 seconds | |
Overload protection (on battery) | 101~109% for 10 seconds and 110~120% for 3 seconds | |
Short circuit protection | UPS output cut off immediately or input fuse/circuit breaker protection | |
System/Display Warning | Visual display | Input/Output Voltage, Input/output Frequency, On-line mode, Back-up mode, Battery Capacity Level, Load Level |
Audible alarm (battery back-up) | Beep every 5 seconds | |
UPS fault | Continuous beeping sound and LCD display | |
Battery | Type | Sealed, maintenance-free lead acid battery |
Typical recharge time | 4 hours to 90% | |
Battery quantity | 12V 7Ah x3 | |
Management | Self-test, adjustable battery transfer pointes and alarm settings | |
Battery protection | Cut off without draining any current when battery is low | |
Cold start (DC start) | Yes | |
Back up time (full load/half load) | 2 to 4 mins/7 to 10 mins | |
General | Input inlet | IEC 320 (230V) |
Receptacles | IEC 320 (230V) | |
Communication interface | RS-232 - USB B-type, Optional SNMP slot | |
Audible Noise | < 45dBA(1m from surface) | |
Operation temperature | 0 ~ 40°C | |
Storage temperature | -20 ~ 50°C | |
Altitude | 2000 meters max | |
Relative humidity | 0-95%, non-condensing | |
Dimensions (mm) | 428 (w) x 425 (d) x 84 (h) | |
Weight | 15.8kg |
Customer ratings & reviews